33 research outputs found

    Adaptation of the Electric Machines Learning Process to the European Higher, Education Area

    Get PDF
    In this paper the basic lines of a complete teaching methodology that has been developed to adaptthe electric machines learning process to the European Higher Education Area (EHEA) arepresented. New teaching materials that are specific to Electric Machines have been created(textbooks, self-learning e-books, guidelines for achieving teamwork research, etc.). Working ingroups has been promoted, as well as problem solving and self-learning exercises, all of which areevaluated in a way that encourages students' participation. Finally, the students' learning process inthe lab has been improved by the development both of a new methodology to follow in the lab andnew workbenches with industrial machines that are easier to use and also enable the labexperiments to be automated. Finally, the first results obtained as a result of applying the proposedmethodology are presented

    Characterization of the Rotor Magnetic Field in a Brushless Doubly Fed Induction Machine.

    Get PDF
    The large increase in wind generation could improve the final development of wind systems with brushless doubly-fed induction machines (BDFIM) as an alternative to the doubly-fed asynchronous machines. For this reason, a detailed study of several aspects of the BDFIM design, as well as of its rotor configuration, is absolutely essential. In this paper, the authors present an alternative formulation of the BDFIM operating principle in synchronous mode. Besides the basic equation of the machine operation, it presents as main advantage the precise characterization of all the magnetic field components in a BDFIM with idealized stator windings and an idealized rotor cage. Based on this formulation, the paper provides a standard that may be used to compare the fields created by different real BDFIMs. This standard has been validated by laboratory tests

    Validation Study of the Use of Matlab/Simulink Synchronous-Machine Block for Accurate Power-Plant Stability Studies

    Full text link
    This paper presents results of the validity study of the use of MATLAB/Simulink synchronous-machine block for power-system stability studies. Firstly, the waveforms of the theoretical synchronous-generator short-circuit currents are described. Thereafter, the comparison between the currents obtained through the simulation model in the sudden short-circuit test, are compared to the theoretical ones. Finally, the factory tests of two commercial generating units are compared to the response of the synchronous generator simulation block during sudden short-circuit, set with the same real data, with satisfactory results. This results show the validity of the use of this generator block for power plant simulation

    New selective earth faults only current directional method for isolated neutral systems

    Full text link
    In order to achieve total selectivity at electrical distribution networks it is of great importance to analyze the defect currents at ungrounded power systems. This information will help to grant selectivity at electrical distribution networks ensuring that only the defect line or feeder is removed from service. In the present work a new selective and directional protection method for ungrounded power systems is evaluated. The new method measures only defect currents to detect earth faults and works with a directional criterion to determine the line under faulty conditions. The main contribution of this new technique is that it can detect earth faults in outgoing lines at any type of substation avoiding the possible mismatch of traditional directional earth fault relays. This detection technique is based on the comparison of the direction of a reference current to the direction of all earth fault capacitive currents at all the feeders connected to the same bus bars. This new method has been validated through computer simulations. The results for the different cases studied are remarkable, proving total validity and usefulness of the new method

    Design and construction of a laboratory bench system for the teaching and training of engineers on diagnostics of permanent magnet motors

    Get PDF
    Permanent magnet synchronous motors PMSM are widely used in industry due to their higher torque and higher power to volume ratio. Moreover they have a better dynamic performance compared to the motors with electromagnetic excitation. Despite its robustness electrical, mechanical and magnetic faults has been described. It has led to the development of specific diagnostic systems for such machines. These systems are constantly evolving according to the literature. In this situation of increasing use of PMSM it is necessary to teach and train professionals in diagnostic techniques. This paper describes the design process of an experimental bench on which can be studied all types of faults associated with the PMSM operation. The design of a PMSM prototype, which is the most important equipment of this bench, is described in more detail

    Consideration of Multi-Phase Criterion in the Differential Protection Algorithm for High-Impedance Grounded Synchronous Generators

    Full text link
    The generator differential protection is one of the most important electrical protections of synchronous generator stator windings. Its operation principle is based on the comparison of the input current and output current at each phase winding. Unwanted trip commands are usually caused by CT saturation, wrong CT selection, or the fact that they may come from different manufacturers. In generators grounded through high impedance, only phase-to-phase or three-phase faults can be detected by the differential protection. This kind of fault causes differential current to flow in, at least, two phases of the winding. Several cases of unwanted trip commands caused by the appearance of differential current in only one phase of the generator have been reported. In this paper multi-phase criterion is proposed for generator differential protection algorithm when applied to high impedance grounded generators

    AVR adjustment of Synchronous Generators in Weak Grids under Faulty Conditions.

    Full text link
    In weak grids, an important problem with voltage stability and protections coordination of power plants exists. This problem appears because all the generation groups are connected to the same bus bar. As a result, if a fault occurs in any of the generation groups, or in the bus bar that connect them, the system voltage will have large oscillations. Hence, in weak grids the correct adjustment of AVR (Automatic Voltage Regulator) is critical. In this work an experimental study of differents AVR adjustments against fault in weak grids is described

    Evaluation of the Grounding Circuit Measurements for Stator Ground-Fault Location of Synchronous Generators

    Full text link
    Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine

    Overall Feasibility of Low Cost Conversion from PV to PVTw

    Get PDF
    La ponencia presenta una comparación entre el rendimiento energético que se obtiene con un módulo fotovoltaico convencional, sin utilizar ningún medio para reducir la temperatura de sus células, y el rendimiento global que resulta si se incorpora a dicho módulo un intercambiador de calor en su parte trasera para reducir la temperatura de sus células y a la vez elevar la temperatura del agua proveniente de la red urbana de abastecimiento. El estudio muestra que el incremento de energia total que se logra mediante la solución propuesta supone una tasa de retorno con un plazo de amortización razonable para este tipo de instalaciones

    New On-Line Excitation-System Ground Fault Location Method Tested in a 106 MVA Synchronous Generator

    Full text link
    In this paper, a novel excitation-system ground-fault location method is described and tested in a 106 MVA synchronous machine. In this unit, numerous rotor ground-fault trips took place always about an hour after the synchronization to the network. However, when the field winding insulation was checked after the trips, there was no failure. The data indicated that the faults in the rotor were caused by centrifugal forces and temperature. Unexpectedly, by applying this new method, the failure was located in a cable between the excitation transformer and the automatic voltage regulator. In addition, several intentional ground faults were performed along the field winding with different fault resistance values, in order to test the accuracy of this method to locate defects in rotor windings of large generators. Therefore, this new on-line rotor ground-fault detection algorithm is tested in high-power synchronous generators with satisfactory results
    corecore